Surgical Robot System — orphan resolution and first-pass closure

System

{{entity:Surgical Robot System}}, session 373. Fourteen top-level subsystems, 80 PART_OF facts, entering this session with 13 orphaned requirements and decomposition status held at in-progress despite prior first-pass note reaching 323 requirements. This session resolves the outstanding orphans, addresses high and medium severity lint findings, and closes the first pass.

Decomposition

No new subsystem decomposition this session. The structural work from prior sessions is complete: all 14 subsystems — {{entity:Motion Control System}}, {{entity:Haptic Feedback Subsystem}}, {{entity:Vision and Imaging Subsystem}}, {{entity:Safety and Interlock Subsystem}}, {{entity:Power Management Subsystem}}, {{entity:Surgical Instrument System}}, {{entity:Energy Delivery System}}, {{entity:Communication and Data Management System}}, {{entity:Surgeon Input Console}}, and supporting subsystems — have been decomposed into components with PART_OF relationships and internal block diagrams.

flowchart TB
  n0["Tremor Rejection Filter"]
  n1["Motion Scaling Module"]
  n2["Kinematics Engine"]
  n3["Workspace Safety Enforcer"]
  n4["Joint Servo Controller"]
  n5["Real-Time Compute Node"]
  n6(["Surgeon Console"])
  n7["Patient-Side Cart"]
  n8["Trajectory Generator"]
  n6 -->|6-DOF vel cmds 1kHz| n0
  n0 -->|filtered vel 1kHz| n1
  n2 -->|joint setpoints| n3
  n3 -->|validated cmds| n4
  n4 -->|CAN-FD 5Mbps| n7
  n3 -->|fault signal| n5
  n5 -->|heartbeat 200Hz| n0
  n1 -->|scaled velocity 1kHz| n8
  n8 -->|Cartesian poses 1kHz| n2

classDef subsystem fill:#f0f5ff,stroke:#2c5282,color:#2c5282

Analysis

Lint reported 138 findings: 4 high, 15 medium, 119 low. The 4 high-severity findings were ontological mismatches — {{entity:Procedure Data Recorder}}, {{entity:Power Management Subsystem}}, {{entity:Real-Time Compute Node}}, and {{entity:Motion Control System}} classified without the {{trait:Physical Object}} trait despite requirements imposing physical constraints. Each had a corresponding physical embodiment requirement (REQ-SESURGICALROBOT-086 through 089) already written by prior sessions but orphaned — the real defect was missing trace links, not missing requirements. These are now acknowledged with substrate facts.

Medium findings included compliance gaps for {{entity:Motion Scaling Module}} ({{sys:SYS-MAIN-008}} → {{sub:REQ-SESURGICALROBOT-092}}, DHF/21 CFR 820.30) and {{entity:Workspace Safety Enforcer}} ({{sys:SYS-MAIN-012}} → {{sub:REQ-SESURGICALROBOT-091}}, SIL 2), plus redundancy gaps for {{entity:Haptic Feedback Subsystem}} ({{sub:REQ-SESURGICALROBOT-096}}) and Time Protocol Engine ({{sub:REQ-SESURGICALROBOT-095}}). All were addressed by the orphaned requirements — again, the issue was trace links.

Concept gap finding 15 (IPA 70% sterility in SYS not cascaded to SUB) was the one genuine gap: no subsystem requirement addressed full-immersion disinfectant resistance for the patient-side cable and adapter hardware.

Requirements

13 orphan trace links created connecting REQ-SESURGICALROBOT-086 through 097 and verification entries 100–101 to their parent system requirements: {{sys:SYS-MAIN-015}} (data recording), {{sys:SYS-MAIN-005}} (60 s power holdover), {{sys:SYS-MAIN-001}} (control loop latency), {{sys:SYS-MAIN-007}} (inter-subsystem synchronisation), {{sys:SYS-MAIN-002}} (single-point failure detection), {{sys:SYS-MAIN-012}} (5 N force limit), {{sys:SYS-MAIN-008}} (motion scaling ratios), and {{sys:SYS-MAIN-006}} (sterile-field safety).

New requirement {{sub:SUB-MAIN-111}} added: the Surgical Instrument System patient-side components (Sterile Adapter, instruments, Cable Tensioning System) SHALL withstand IPA 70% full immersion for 30-minute contact time without structural or barrier degradation. Derives from {{sys:SYS-MAIN-006}}. Verification entry {{sub:VER-MAIN-119}} created: 30-minute immersion test with sterile barrier, cable tension, and visual inspection pass criteria. Trace chain: SYS-MAIN-006 → SUB-MAIN-111 → VER-MAIN-119.

Final state: 420 requirements, 0 orphans, 384 trace links, baseline DECOMP-2026-03-20 created. Decomposition status set to first-pass-complete.

Next

QC session (Flow C) required. Priority items: 14 top-level subsystems with naming inconsistencies (Motion Control System vs Motion Control and Scaling Subsystem; Vision and Imaging Subsystem vs Vision and Imaging System) should be rationalised and PART_OF facts deduplicated. Lint acronym findings (119 low-severity) can be batch-acknowledged. Verification coverage for SUB requirements below 50% should be identified and closed.